Heparin Dosing Nomogram
Weight-Based Nomogram
| Measured Value | Adjustment |
| APTT <35sec(<1.2×control value) | 80u/kg IV bolus, and increase IV infusion rate by 4u/kg/hr |
| APTT 35-45sec(1.2-1.5×control value) | 40u/kg IV bolus, and increase IV infusion rate by 2u/kg/hr |
| APTT 46-70sec(>1.5-2.3×control value) | No change |
| APTT 71-90sec(>2.3-3×control value) | Decrease IV infusion rate by 2u/kg/hr |
| APTT >90sec(>3×control value) | Stop infusion for 1hr, then decrease IV infusion rate by 3u/kg/hr |